COTRAN 932 Wear-Resistant Insulating Repair Tape

COTRAN 932 is made of special chlorosulfonated polyethylene rubber as the base material, supplemented by two tacky mastic layers of flame retardant and waterproof. It can meet the wear-resistant, waterproof and fire-resistant needs of sheath repair for all types of cables. COTRAN 932 is used to repair of mining cables, outer jacket of mining cable splice kits and splicing of mine conduit.

Product Features

  • The outer layer is made of super wear-resistant material
  • Unique three-layer composite structure, excellent waterproof performance
  • Lead-free flame retardant, good thermal conductivity
  • Oil and corrosion resistance, acid and alkali resistance and various chemical corrosion
  • Anti-ozone, ultraviolet, xenon lamp aging


Technical Properties

No.

Performance indicators

Typical value

Test method

1

Thickness

1.30 mm

ASTM D 1000

2

Tensile strength

7.0 MPa

ASTM D 412

3

Elongation at break

500%

ASTM D 412

4

Thermal aging test (90℃/168h)

Through

ASTM D 4325

5

Waterproof grade

IPX8

GB/T 4208-2008

6

Flame retardant grade

V-1

UL 94

7

Dielectric strength

10kV/mm

ASTM D 4325


Installation

1. Clean the dust and oil on the covered surface;

2. Remove the product release paper, the stretching rate is 10%~ 50%, and the winding is wound with 50% overlap rate;

3. The starting point and ending point of tape winding exceed 30~ 50mm at both ends of the coating part.


Specification

Width × Thickness × Length: 51mm × 1.3mm × 2.6m;

Packing information: 20 rolls/carton


Storage

COTRAN 932 should be stored in original packaging, placed in horizontal position under cover and in a humidity controlled storage (5°C to 35°C and <75% relative humidity).

Leave A Message
If you are interested in our products and want to know more details,please leave a message here,we will reply you as soon as we can.
Related products
Roll Bonded Liquid Cooling Plate
Battery Energy Storage Roll Bonded Liquid Cooling Plate

◆High production efficiency

◆Large thermal contact area

◆Uniform and stable welding

◆Rapid thermal cooling speed

◆Thin thickness to save space

◆Easy processing and shaping

◆Good thermal exchange effect

◆Low leak risk and high security

Cylindrical Battery Water Cooling Tube
New Energy Vehicle Cylindrical Battery Water Cooling Tube

◆Large thermal dissipation area

◆High thermal dissipation efficiency

◆Low leakage risk and high reliability

◆Stable and high production efficiency

◆Reduce the weight of the battery pack

◆Low energy for single cylindrical battery

◆Improve the battery life and performance

◆Less pollution and environmental protection

Aluminum Water Cooling Plate
Power Battery Pack Aluminum Water Cooling Plate

◆High production efficiency

◆Large thermal transfer area

◆Flexible flow channel design

◆Rapid thermal cooling speed

◆Thin thickness to save space

◆Easy processing and shaping

◆Goodthermal exchange effect

◆Low leak risk and high security

Stamping Liquid Cooling Plate
New Energy Automobiles Stamping Liquid Cooling Plate

◆Excellent surface flatness

◆Large thermal transfer area

◆Flexibleflow channel design

◆Easyprocessing and shaping

◆Goodthermaldissipation effect

◆Low leakage risk and high safety

◆Good pressure resist and strength

◆High production efficiency and yield

Anti-corrosion Primer
Primer for Anti-Corrosion Tape
The anticorrosive primer and PE anticorrosive tape together constitute the polyethylene cold wound anticorrosive system. Coated on the surface treatment of steel tube, can fill a small bump on the surface of the steel tube, and can increase the adhesive tape with sticky relay between steel tube, at the same time it is also a kind of excellent corrosion inhibitor.
Porcelain Insulator Outdoor Termination
64/110kv YJZWY Outdoor Termina Tion With Porcelain Insula Tor For 64/110kv XLPE Cable
Termination with porcelain insulator is mainly comprised of porcelain sheath, stress cone, tail pipe, supporting insulator, lug and other accessories. Porcelain sheath has the structure of high strength electrical porcelain and rain-shed of different sizes. It is with good antipollution flashover performance and the porcelain sheath is filled with polyisobutene. This product has mature operational experience and reliable quality.
Flexible Fireproof and Explosion-proof Blanket
Flexible Fireproof and Explosion-proof Blanket KC9001

KC9001 Flexible fireproof and explosion-proof blanket is suitable for the outer wrapping of the cable straight joint. It adopts multi-layer protective structure to cover the cable straight joint. The outer layer is made of ablation-resistant fireproof cloth with built-in flexible nano thermal insulation sheet and high strength aramid fiber cloth. When the fire broke out, the built-in can flexible nano can get insulation sheet is 3 ~ 4 times of that of the traditional performance, at the same time the highest heat resistance is above 1200 ℃, and it has excellent flame retardant and heat insulation effect, and the built-in high strength aramid fiber cloth can avoid the middle joint breakdown exploded the harm of adjacent cables, avoid the secondary damage caused by the fire. KC9001 light flexible fireproof blanket is easy to install, and it can be easily installed outside the cable intermediate connector after construction by means of pre-installed fire-resistant tie belt and D-type ring clasp without other tools.

Moisture Proof Sealing Material KC3000
Moisture Proof Sealing Material KC3000

KC3000 Moisture proof sealing material is widely used for moisture proof sealing in distribution control cabinet, RMU, HV/LV switch cabinet, cable branch box, terminal box, pad-mounted transformer, mechanism operation box, assembly control unit, which has low viscosity, good fluidity and easy penetration, resistant to natural freeze-thaw cycle and all kinds harsh environment, while no deformation, no deterioration, no cracking.

With a variety of metal materials, cable sheath material can be closely bonded and not corroded, but also effectively prevent small animals from underground into the cabinet, reduce safety risks; to realize the closed cabinet moisture proof, prevent cable interlayer or channel from moisture, to provide reliable protection for production and operation equipment.

Subscribe
Subscribe to our newsletter and stay up to date with the latest news and deals !

click here to leave a message

Leave A Message
If you are interested in our products and want to know more details,please leave a message here,we will reply you as soon as we can.

Home

Products

About

contact