EPR High Voltage Insulation Tape KC71

◆ Can be used to splice and terminate cable, the emergency overload temperatures can reach 130℃.

◆ Based on Ethylene Propylene Rubber(EPR).

◆ Physical and electrical properties are unaffected by the degree of stretch.

◆ Self-fusing tape.

◆ Excellent electrical properties.

◆ A special polyester liner which will not stick to the tape upon unwind.

◆ Operation and installation easily.

◆ Compatible with all solid dielectric cable insulation:

Polyethylene (high and low density).

Cross-linked polyethylene (XLPE).

Polyvinyl chloride (PVC).

Butyl rubber.




Product Description 

Cotran Brand KC71 EPR High Voltage Insulation Tape is a highly conformable, self-fusing ethylene propylene

rubber(EPR), high insulting tape. KC71 is used for main insulation applications of cableand other electrical devices up to69KV.


Applications

◆ Electrical insulation jacketing in splices of solid dielectric cable up to 69kV.

◆ Building stress cones in terminations of solid dielectric cable up to 35kV.

◆ Jacketing of indoor terminations.

◆ Moisture sealing electrical connections.

◆ Bus bar insulations and corrosion protection.

◆ End sealing high-voltage cables.

◆ Jacket repair and restoration in all types of cable.


Test Parameters

No.

Test Item

Typical Value

Test Method

1

Color

Black

Visual

2

Thickness

0.76mm

ASTM D4325

3

Tensile Strength

2.3MPa

ASTM D4325

4

Elongation at Break

750%

ASTM D4325

5

Dielectric Strength

32KV/mm

ASTM D1000

6

Volume resistivity

6.2x1014Ώ.cm

ASTM-D4325

7

Fusion

Pass

ASTM D4388

8

Heat ageing(130℃ 168H)

Pass

ASTM D4325

9

UVageing

Pass

ASTM D4325

10

Xenon ageing

Pass

ISO 4892-2


Installation

Cotran Brand KC71 EPR High Voltage Insulation Tape should be applied in successive half-lapped, level-wound layers until desired build-up is reached.

Step 1 Perform normal cable preparation, and remove separator from tape;




Step 2 Apply tape half-lapped, stretching the tape 100%, which is enough to reduce its width to around 2/3 of its original width;


Step 3 Finish breaking the tape by holding it with your thumb and stick the end well.



Leave A Message
If you are interested in our products and want to know more details,please leave a message here,we will reply you as soon as we can.
Related products
Thermal conductive Insulating Tape
EPR Electrical Semi-conducting Tape KC72

◆ Can be used to repair XLPE cable terminations and joints or shielding for other devices up to 110kV.

◆ Retains its conductivity when stretched.

◆ Semi-conducting (low resistivity).

◆ Suitable for irregular shapes cable with good elongation.

◆ Withstand high temperatures (130°C/266°F) short-term overload.

◆ Compatible with all solid dielectric cable insulations and conductors.

◆ Resistance to ozone, solvents, UV, xenon exposure and moisture.

◆ Suitable for indoor or outdoor applications.

◆ Operation and installation easily.

◆ Increases its conductance and will not harm it in any way.

Waterseal Mastic Tape
KC80 Waterproof Insulation Waterseal Mastic Tape
◆ Continuous waterproofing.
◆ Highly self-fusing tape.
◆ Suitable for irregular shapes cable.
◆ Resistance to high/low temperature.
◆ Resistance to corrosion.
◆ Resistance to ozone, UV, xenon exposure.
◆ New formulation for insulation.
◆ Operation and installation easily.
◆ Excellent adhesion to copper, aluminum and cable jacket.
Cylinder Battery Harmonica Tube
Electric Automobile Power Cylindrical Battery Harmonica Tube

◆Large thermal dissipation area

◆Battery side thermal dissipation

◆High thermal dissipation efficiency

◆Low leakage risk and high reliability

◆Stable and high production efficiency

◆Reduce the weight of the battery pack

◆Low energy for single cylindrical battery

◆Improve the battery life and performance

Cell Water Cooling Plate
Energy Storage System Cell Water Cooling Plate

◆High production efficiency

◆Large thermal transfer area

◆High performance cost ratio

◆Rapid thermal cooling speed

◆Thin thickness to save space

◆Easy processing and shaping

◆Good thermal exchange effect

◆Low leak risk andhigh reliability

Insulation Piercing Connector
COTRAN Insulation Piercing Connector (JJC series)
Product Applications COTRAN JJC series insulation piercing connectors are applicable for all types of LV-ABC conductors as well as connections in service line system, building electrical system and street lighting system. installation of JJC can be easily done by tightening bolts to forceteeth penetrate insulation of main line and tap line simultaneously. Stripping of insulation is avoided for both lines. Feature Material: insulation material made of weather resistant polymer. Contact teeth made of tinned brass or copper or aluminum. Meet standard requirements: EN 50483-4, NF C33-020, NF C33-004 Specification Type Main line section (mm²) Branch section (mm²) rated current (A) Dimensions  (mm) Weight (g) Piercing Depth (mm) No. of bolts JJC888 0.75-6 0.75-6 41 21*27*23 10 1-1.5 1 JJC-1 1.5-25 1.5-10 55 27*41*62 55 1.5-2 1 JJC-2 16-95 1.5-10 55 27*41*62 55 1-2 1 JJC-3(A) 6-50 4-25 157 42*45*62 110 2.5-3.5 1 JJC-3 16-95 4-35(50) 157 46*52*87 160 2.5-3.5 1 JJC-4 50-150 6-35(50) 157 46*52*87 162 2.5-3.5 1 JJC-5 25-95 25-95 214 50*61*100 198 3-4 1 JJC-5-1 16-120 16-120 214 50*61*100 198 3-4 1 JJC-6 (35)50-150 (35)50-150 316 50*61*100 280 3-4 1 JJC-7 120-240 25-120 276 52*68*100 360 3-4 1 JJC-7-1 150-240 10-25 102 52*68*100 336 3-4 1 JJC-8 95-400 35-300 425 83*130*130 1050 5-6 2
Heat Shrink Double layer Tube
Heat Shrink Semi-Conductive/Insulation Double layer Tube (1~36kV)

Applications:

The tubing manufactured with special technology, is very suitable for applications in power cable joints up to 36kV.

Aluminum Water Cooling Plate
Power Battery Pack Aluminum Water Cooling Plate

◆High production efficiency

◆Large thermal transfer area

◆Flexible flow channel design

◆Rapid thermal cooling speed

◆Thin thickness to save space

◆Easy processing and shaping

◆Goodthermal exchange effect

◆Low leak risk and high security

Flexible Cold Shrink Tube
Customized silicone rubber cold shrink tube enRR-CST

IPX8 class, stable and long-life during operation

Easy to install, only two steps (Cover, pull)

Fast installation, only 15-30 seconds needed to seal one connection

No limitation of spare space, especially design for MIMO &massive MIMO Antenna, also convenient to deploy on wall-mounted, high tower, pole-mounted condition etc.,

Easy to uninstall, only need knife to cut tube open

No skill required by engineers, uniform quality after installation, stable and good sealing and weatherproofing performance

Much time cost, and labor cost saving

Good operating capability under extreme cold and hot condition, highland, salt-mist situation, heavy windy weather, and anti-UV, anti-ozone


Subscribe
Subscribe to our newsletter and stay up to date with the latest news and deals !

click here to leave a message

Leave A Message
If you are interested in our products and want to know more details,please leave a message here,we will reply you as soon as we can.

Home

Products

About

contact