Electrical Insulating Filler Tape KC78

High tensile strength and bonding strength.
Suitable for irregular shapes cable with good elongation.
Ensuring high quality seal over a wide range of temperatures.
Physical and electrical properties are unaffected by the degree of stretch.
Self-fusing tape.
Good chemical resistance, weather resistance and corrosion resistance.
Excellent ageing properties.
Excellent electrical properties.
Operation and installation easily.

Cotran Brand KC78 Electrical Insulation Filler Tape is a conformable, flexible, self-fusing butyl-based, waterproofing mastic tape. It provides excellent resistance to varying weather, aging, and it also provides excellent adhesion to metals, cable insulations and jacket. This product can be used in sealant as a waterproofing filler for low voltage cable terminations and joints. 


Applications

◆ To insulate low-voltage (below 600V) connections.
◆ To build up cable splices and fill out major irregularities and voids in low-voltage splices (below 2300V).
◆ To create a uniform base in irregular cable end for further overwrapping.
◆ To smooth bus bar irregularities.
◆ To be a moisture seal at grounding wire.
◆ To be a sealant with excellent adhesion to cable jackets and other insulating materials.


Test Parameters

No.

Test Item

Result

Test Method

1

Color

Black

 

2

Thickness

3.18mm

 

3

Tensile Strength

3.72N/10mm

ASTM D1000

4

Elongation at Break

>602%

ASTM D1000

5

Insulation resistance

1.53x1013 Ώ.cm

ASTM D1000

6

Copper corrosion

None

ASTM D69


Installation

Cotran Brand KC78 eletrical insulation filler tape should be applied in successive half-lapped, level-wound layers until desired build-up is reached.

Step 1 Wipe off the dusts on the splice area before wrapping.

 

Step 2 Remove the liner and stretch the tape to 1 to 2 times of its original length, apply the tape in 50%-lapped with mastic side toward area to the wrapped. Stretching the tape to 4 times of its original length is not recommended.

 

Step 3 Finish breaking the tape by holding it with your thumb and stick the end well.

 

Step 4 AfterKC78 electrical insulation filler tape is applied, overwrapping COTRAN PVC insulation tape is recommended, apply 3 layers of COTRAN PVC insulation tape in a 50% overlapping with no tension. Make sure not to overstretch the PVC tape during installation.

Leave A Message
If you are interested in our products and want to know more details,please leave a message here,we will reply you as soon as we can.
Related products
Micro-channel Harmonica Liquid Cooling Tube
Aluminum Extruded Micro-channel Harmonica Liquid Cooling Tube

◆Large thermal dissipation area

◆High thermal dissipation efficiency

◆Low leakage risk and high reliability

◆Stable and high production efficiency

◆Reduce the weight of the battery pack

◆Low energy for single cylindrical battery

◆Improve the battery life and performance

◆Less pollution and environmental protection

Insulated Gis Termination
64/110KV YJZGG Dry Insulated Gis Termination For 64/110kv Xlpe Cable
Dry GIS termination has composite structure of stress cone and epoxy sheath, making the surface of pre-fabricated stress cone clinged to the inner wall of epoxy sheath through spring assembly to reach reasonable interface pressure.
Screen Separable Cable Connector
Screen Separable Cable Connector (6~36kV)

Applications:

The Separable Connector establishes the connection between any polymeric insulated cable onto transformers, switchgears, motors or other equipment.





PIB Self Amalgamating Tape
PIB Self-Fusing Electrical Tape KC74
KC74 self amalgamating tape for insulating and moisture sealing of telecommunication cable connections For insulation and moisture sealing in splices and terminations of solid dielectric power cable up to 10kVFor general-purpose protection and waterproofingFor corrosion protection of metal pipework.
Heat Shrink Breakout
Heat Shrink 3 Cores Conductive Breakout (1~36kV)

Applications:

The electrically semi-conductive property of the breakout provides effective conductive screen and sealing protection to the cable terminations. The breakout can be used to cable terminations up to 36kV.


Fire Retardant Coating for Electrical Cables
Cable Fireproof Coating KC2000

◆ Completely meet the requirements of GB 28374-2012;

◆ Environmental protection halogen-free, non-toxic and harmless;

◆ Good flexibility;

◆ Good insulation performance;

◆ Strong adhesion;

◆ Good fire protection effect;

◆ Good anti-corrosion performance.

Roll Bonding Water Cold Plate
Energy Storage System Roll Bonding Water Cold Plate

◆High production efficiency

◆Large thermal transfer area

◆High performance cost ratio

◆Rapid thermal cooling speed

◆Thin thickness to save space

◆Easy processing and shaping

◆Good thermal exchange effect

◆Low leak risk and high reliability

Oil Resistant Filling Mastic
Oil Resistant Filling Mastic

Applications:

To provide oil resistance, void filling and sealing for oil-immersed cable termination and joints for heat shrink technology up to 36kV.