Electrical Insulating Filler Tape KC78

◆ High tensile strength and bonding strength.
◆ Suitable for irregular shapes cable with good elongation.
◆ Ensuring high quality seal over a wide range of temperatures.
◆ Physical and electrical properties are unaffected by the degree of stretch.
◆ Self-fusing tape.
◆ Good chemical resistance, weather resistance and corrosion resistance.
◆ Excellent ageing properties.
◆ Excellent electrical properties.
◆ Operation and installation easily.

Cotran Brand KC78 Electrical Insulation Filler Tape is a conformable, flexible, self-fusing butyl-based, waterproofing mastic tape. It provides excellent resistance to varying weather, aging, and it also provides excellent adhesion to metals, cable insulations and jacket. This product can be used in sealant as a waterproofing filler for low voltage cable terminations and joints. 


Applications

◆ To insulate low-voltage (below 600V) connections.
◆ To build up cable splices and fill out major irregularities and voids in low-voltage splices (below 2300V).
◆ To create a uniform base in irregular cable end for further overwrapping.
◆ To smooth bus bar irregularities.
◆ To be a moisture seal at grounding wire.
◆ To be a sealant with excellent adhesion to cable jackets and other insulating materials.


Test Parameters

No.

Test Item

Result

Test Method

1

Color

Black

 

2

Thickness

3.18mm

 

3

Tensile Strength

3.72N/10mm

ASTM D1000

4

Elongation at Break

>602%

ASTM D1000

5

Insulation resistance

1.53x1013 Ώ.cm

ASTM D1000

6

Copper corrosion

None

ASTM D69


Installation

Cotran Brand KC78 eletrical insulation filler tape should be applied in successive half-lapped, level-wound layers until desired build-up is reached.

Step 1 Wipe off the dusts on the splice area before wrapping.

 

Step 2 Remove the liner and stretch the tape to 1 to 2 times of its original length, apply the tape in 50%-lapped with mastic side toward area to the wrapped. Stretching the tape to 4 times of its original length is not recommended.

 

Step 3 Finish breaking the tape by holding it with your thumb and stick the end well.

 

Step 4 AfterKC78 electrical insulation filler tape is applied, overwrapping COTRAN PVC insulation tape is recommended, apply 3 layers of COTRAN PVC insulation tape in a 50% overlapping with no tension. Make sure not to overstretch the PVC tape during installation.

Leave A Message
If you are interested in our products and want to know more details,please leave a message here,we will reply you as soon as we can.
Related products
Heat Shrink Stress Control Tube
Heat Shrink Stress Control Tube (36kV)

Applications:

The specially designed chemical formulation and carefully controlled manufacture technology effectively release the high electrical stress present at insulation screen in termination and joint of power cables up to 36kV.

Aluminum Water Cooled Plate
Battery Energy Storage System Aluminum Water Cooled Plate

◆High production efficiency

◆Large thermal contact area

◆Uniform and stable welding

◆Rapid thermal cooling speed

◆Thin thickness to save space

◆Easy processing and shaping

◆Good thermal exchange effect

◆Low leak risk and high security

Micro-channel Harmonica Liquid Cooling Tube
Aluminum Extruded Micro-channel Harmonica Liquid Cooling Tube

◆Large thermal dissipation area

◆High thermal dissipation efficiency

◆Low leakage risk and high reliability

◆Stable and high production efficiency

◆Reduce the weight of the battery pack

◆Low energy for single cylindrical battery

◆Improve the battery life and performance

◆Less pollution and environmental protection

Harmonica Cooling Tube
Electric Vehicle Power Battery Harmonica Cooling Tube

◆Large thermal dissipation area

◆High thermal dissipation efficiency

◆Low leakage risk and high reliability

◆Stable and high production efficiency

◆Reduce the weight of the battery pack

◆Low energy for single cylindrical battery

◆Improve the battery life and performance

◆Less pollution and environmental protection

Power Battery Snake Tube
New Energy Vehicle Power Battery Snake Tube

◆High material utilization

◆Battery side heat dissipation

◆Large thermal dissipation area

◆High thermal dissipation efficiency

◆Low leakage risk and high reliability

◆Stable and high production efficiency

◆Reduce the weight of the battery pack

◆Improve the battery life and performance

Heat Shrink Double layer Tube
Heat Shrink Semi-Conductive/Insulation Double layer Tube (1~36kV)

Applications:

The tubing manufactured with special technology, is very suitable for applications in power cable joints up to 36kV.

Anticorrosive waterproof coating
Solvent-free Insulating Anticorrosive Waterproof Coating KC1000

KC1000 is a solvent-free insulating anticorrosive waterproof coating, bubble is in water for a long time still can maintain the performance, can reduce the corrosion of corrosive environment of electric equipment, can reduce the snakes, rats, birds, small animals such as the cause of disaster risk, also can reduce because of the extreme weather (the typhoon, rain and snow, etc.) caused by accidents, provide long-term stable safe protection for power supply.

Brazing Liquid Cooling Sheet
Energy Storage Battery Pack Brazing Liquid Cooling Sheet

◆High production efficiency

◆Large thermal transfer area

◆Flexible flow channel design

◆Rapid thermal cooling speed

◆Thin thickness to save space

◆Easy processing and shaping

◆Good thermal exchange effect

◆Low leak risk and high security

Subscribe
Subscribe to our newsletter and stay up to date with the latest news and deals !

click here to leave a message

Leave A Message
If you are interested in our products and want to know more details,please leave a message here,we will reply you as soon as we can.

Home

Products

About

contact