EPR Electrical Semi-conducting Tape KC72

◆ Can be used to repair XLPE cable terminations and joints or shielding for other devices up to 110kV.

◆ Retains its conductivity when stretched.

◆ Semi-conducting (low resistivity).

◆ Suitable for irregular shapes cable with good elongation.

◆ Withstand high temperatures (130°C/266°F) short-term overload.

◆ Compatible with all solid dielectric cable insulations and conductors.

◆ Resistance to ozone, solvents, UV, xenon exposure and moisture.

◆ Suitable for indoor or outdoor applications.

◆ Operation and installation easily.

◆ Increases its conductance and will not harm it in any way.

Product Description 


Cotran Brand KC72 electrical semi-conducting tape is a Highly conformable, self-fusing, semi-conducting ethylene

propylene rubber(EPR) based, high voltage splicing tape. KC72 is used for repairing of XLPE cable terminations

and joints or shielding for other devices up to 110kV.


Applications


◆ Uniform electric field in high electric field, to minimize electrical stresses in

◆ Continue semi-conducting strand shielding found in solid dielectric cables above 5kV.

◆ Provide shielding layer for solid dielectric insulated cable.

◆ Repair the semi-conducting layer beneath metallic shield of similar cables in case of damage

◆ Make conductive portion of stress cone of power cable termination on solid dielectric insulated cables.


Test Parameters

No.

Test Item

Result

Test Method

1

Color

Black


2

Thickness

0.76mm

ASTM D4325

3

Tensile Strength

3.83MPa

ASTM D4325

4

Elongation at Break

850%

ASTM D4325

5

Dielectric Strength

35.16Kv/mm

ASTM D1000

6

Volume resistivity

3.5x1015Ώ.cm

ASTM-D4325

7

Fusion

Pass

ASTM D4388

8

Heat ageing(130℃ 168H)

Pass

ASTM D4325

9

UVageing

Pass

ASTM D4325

10

Xenon ageing

Pass

ISO 4892-2


Installation


Cotran Brand KC72 electrical semi-conducting tape is usually wrapped in half-lapped layers. With excellent elongation, stretched overwrapping the connectors, terminals, and metallic shield of power cable.

Step 1 Wipe off the dusts on the power cable area before wrapping.




Step 2 Remove the liner and stretch the tape to 1 to 2 times of its original length, apply the tape in 50%-lapped toward area to the wrapped. Stretching the tape to 4 times of its original length is not recommended.



Step 3 Overwrapping the electrical semi-conducting tape on the power cable on the needed area.





Leave A Message
If you are interested in our products and want to know more details,please leave a message here,we will reply you as soon as we can.
Related products
adhesive insulation tape
EPR High Voltage Insulation Tape KC71

◆ Can be used to splice and terminate cable, the emergency overload temperatures can reach 130℃.

◆ Based on Ethylene Propylene Rubber(EPR).

◆ Physical and electrical properties are unaffected by the degree of stretch.

◆ Self-fusing tape.

◆ Excellent electrical properties.

◆ A special polyester liner which will not stick to the tape upon unwind.

◆ Operation and installation easily.

◆ Compatible with all solid dielectric cable insulation:

Polyethylene (high and low density).

Cross-linked polyethylene (XLPE).

Polyvinyl chloride (PVC).

Butyl rubber.




Electrical Insulation Silicone Rubber Tape
Heat Resistant Silicone Rubber Electrical Tape KC73
Highly tracking resistance
Resistance to solvents
Withstand high/low temperature
Resistance to ozone, UV, and xenon exposure
Brazed Water Cooling Sheet
Electric Automobile Power Battery Brazed Water Cooling Sheet

◆Rapid thermal cooling speed

◆Thin thickness to save space

◆Easy processing and shaping

◆Large thermal dissipation area

◆High thermal dissipation effect

◆Flexible runner channel design

◆Excellent welding performance

◆Low leak risk and high security

Insulation Piercing Connector
COTRAN Insulation Piercing Connector (JJC series)
Product Applications COTRAN JJC series insulation piercing connectors are applicable for all types of LV-ABC conductors as well as connections in service line system, building electrical system and street lighting system. installation of JJC can be easily done by tightening bolts to forceteeth penetrate insulation of main line and tap line simultaneously. Stripping of insulation is avoided for both lines. Feature Material: insulation material made of weather resistant polymer. Contact teeth made of tinned brass or copper or aluminum. Meet standard requirements: EN 50483-4, NF C33-020, NF C33-004 Specification Type Main line section (mm²) Branch section (mm²) rated current (A) Dimensions  (mm) Weight (g) Piercing Depth (mm) No. of bolts JJC888 0.75-6 0.75-6 41 21*27*23 10 1-1.5 1 JJC-1 1.5-25 1.5-10 55 27*41*62 55 1.5-2 1 JJC-2 16-95 1.5-10 55 27*41*62 55 1-2 1 JJC-3(A) 6-50 4-25 157 42*45*62 110 2.5-3.5 1 JJC-3 16-95 4-35(50) 157 46*52*87 160 2.5-3.5 1 JJC-4 50-150 6-35(50) 157 46*52*87 162 2.5-3.5 1 JJC-5 25-95 25-95 214 50*61*100 198 3-4 1 JJC-5-1 16-120 16-120 214 50*61*100 198 3-4 1 JJC-6 (35)50-150 (35)50-150 316 50*61*100 280 3-4 1 JJC-7 120-240 25-120 276 52*68*100 360 3-4 1 JJC-7-1 150-240 10-25 102 52*68*100 336 3-4 1 JJC-8 95-400 35-300 425 83*130*130 1050 5-6 2
Insulating Vinyl Backing Mastic Tape
Electrical Insulation Waterproof Vinyl Mastic Tape KC75
KC75 is a self-fusing, conformable, vinyl backing mastic tape. KC75 seals out moisture and protects against corrosion without the need for heating tools or using multiple tapes. KC75 is designed for cable sheath repair, low voltage insulating, conduit repair and protection of CATV components as well as other general taping applications. Application Electrostatic shielding solid dielectric cable connector and terminal Filling all kinds of irregular joint Repair of high-voltage connector conductor shielding layer Other shielding occasions Technical Data Property Typical Value Test Method Adhesion to steel 18.7N/10mm ASTM D 1000 Adhesion to PE 20.2N/10mm ASTM D 1000 Dielectric strength 21KV/mm ASTM D 4325 Volume Resistivity 1.66*10^34 Ω ASTM D 1000 Water Absorption 0.2% ASTM D 4325 Packing Part No. Dimension Color Rolls/Case KC75 38mm*0.635mm*6m Black 40 Note: Other size is available on request.
Non-solidified Sealing Moisture-proof Silicone Mastic
Non-solidified Sealing Moisture-proof Silicone Mastic KC6000

KC6000 is a kind of dry silicone Mastic, with good viscosity, high temperature resistance (100℃), cold resistance (-40℃), waterproof insulation and fire resistance, never dry and other excellent properties. The product does not contain volatile organic compounds, environmental protection, safety, non-corrosive, suitable for switch cabinets, ring network cabinets, electrical joints, high-speed railway, subway, light rail and other waterproof sealing filling and insulation, easy to form, especially suitable for irregular structure of internal and external sealing

Heat Shrink Double layer Tube
Heat Shrink Semi-Conductive/Insulation Double layer Tube (1~36kV)

Applications:

The tubing manufactured with special technology, is very suitable for applications in power cable joints up to 36kV.

Insulating Repair Tape
COTRAN 932 Wear-Resistant Insulating Repair Tape

COTRAN 932 is made of special chlorosulfonated polyethylene rubber as the base material, supplemented by two tacky mastic layers of flame retardant and waterproof. It can meet the wear-resistant, waterproof and fire-resistant needs of sheath repair for all types of cables. COTRAN 932 is used to repair of mining cables, outer jacket of mining cable splice kits and splicing of mine conduit.

Subscribe
Subscribe to our newsletter and stay up to date with the latest news and deals !

click here to leave a message

Leave A Message
If you are interested in our products and want to know more details,please leave a message here,we will reply you as soon as we can.

Home

Products

About

contact