banner
  • Marking Plate Plastic
    Marking Plate Plastic for Identify Cables Radio and Antenna

    Marking set to identify cables for radio and antenna. Made of high quality plastic to suit for outdoor application.


  • Stainless Steel Marking Plate
    Stainless Steel Marking Plate for Cable
    ◆ High tensile strength
    ◆ Rust poof
    ◆ Non-flammability
    ◆ Anti corrosion
    ◆ Weatherproof and UV resistant
    ◆ High resistance to aceticacid,alkaliacid,suiphuric acid, acorrode etc
  • Cable Grounding kit
    Universal Framework Type Grounding Kits
    Can provide several type of cables, such as 1/4”, 1/2”, 7/8”, 5/4”, 13/8”, etc;
    Compact structure;
    Faster and easy installation;
    Contact resistance < 5mΩ;
    Weatherproofing IP67;
    No extra taping kit needed;
    UV and corrosion resistant;
  • Stainless Steel Feeder Cable Clamp
    Three Way Through Type Feeder Cable Clamp
    Three Way Through Type Feeder Cable Clamp
    1. Through Type Feeder Clamps for coaxial, fiber optic, power, hybrid and aerial cables;
    2. The clamp is designed to support cables with the dimensions of 1/4”, 1/2”, 7/8”, 5/4”, 13/8”, 1/2”s, etc;
    3. Quick and easy to install and operate;
    4. Without additional adapters, provide sturdy, reliable, long-term support;
    5. Wind loaded, UV and corrosion resistant;
    6. Capable to working in extreme temperature;
  • Double Cable Clamp
    Feeder Double Cable Clamp with Cushion Inserts
    Feeder Double Cable Clamp with Cushion Inserts
    1. Quick and easy to install and operate;
    2. Without additional adapters, provide sturdy, reliable, long-term support;
    3. Wind loaded, UV and corrosion resistant;
    4. Capable to working in extreme temperature;
  • 7/16 Straight Female Connector
    7/16 Straight Female Connector for 7/8" Flexible RF Cable
    Material and Plating Inner Conductor Pin Brass / Silver Plating Inner Conductor Socket Tin Bronze / Silver Plating Insulator PTFE/TPX Body & Outer Conductor Brass / Trimetal Plating Gasket Silicon Rubber Electrical Specifications Characteristics Impedance 50 Ohm Frequency Range DC~7.5GHz Insulation Resistance ≥10000MΩ Dielectric Withstanding Voltage 4000V rms Operating Voltage 2700V rms Center contact resistance ≤0.4 mΩ Outer contact resistance ≤0.2 mΩ Insertion Loss @DC-2.7 GHz ≤0.10dB VSWR @0.8-1.0 GHz ≤1.08  @1.7-2.7 GHz ≤1.10 PIM3(2*43dBm) ≤-155dBc Environmental & Mechanical Specifications Durability (matings) ≥500 cycles Mechanical Shock Test Method MIL-STD-202, Method 213, Test Condition D Vibration Test Method MIL-STD-202, Meth. 204, Cond. A Temperature Range -65°C to +85°C RoHS Compliant Sealing Class IP68 24hr, 1m, 20℃ Regulatory Compliance / Certification ISO 9001:2015 Compliant The facts and figures contained herein are carefully complied to the best of our knowledge, but they are intended for general informational purposes only.
  • 7/16 Straight female Connector
    7/16 Straight female Connector for 1-5/8 Flexible RF Cable
    Material and Plating Inner Conductor Pin Brass / Silver Plating Inner Conductor Socket Tin Bronze / Silver Plating Insulator TPX Body & Outer Conductor Brass / Trimetal Plating Gasket Silicon Rubber Electrical Specifications Characteristics Impedance 50 Ohm Frequency Range DC~2.7GHz Insulation Resistance ≥5000MΩ Dielectric Withstanding Voltage 4000V rms Operating Voltage 2500V rms Center contact resistance ≤0.4 mΩ Outer contact resistance ≤0.2 mΩ Insertion Loss @DC-2.7 GHz ≤0.10dB VSWR @0.8-1.0 GHz ≤1.10  @1.7-2.7 GHz ≤1.13 PIM3(2*43dBm) ≤-155dBc Environmental & Mechanical Specifications Durability (matings) ≥500 cycles Mechanical Shock Test Method MIL-STD-202, Method 213, Test Condition D Vibration Test Method MIL-STD-202, Meth. 204, Cond. A Temperature Range -65°C to +85°C RoHS Compliant Sealing Class IP68 24hr, 1m, 20℃ Regulatory Compliance / Certification ISO 9001:2015 Compliant The facts and figures contained herein are carefully complied to the best of our knowledge, but they are intended for general informational purposes only.
  • 4.3-10 Straight Female Connector
    4.3-10 Straight Female Connector for 7/8" Flexible RF Cable
    Material and Plating Inner Conductor Pin Tin Bronze / Silver Plating Inner Conductor Socket Tin Bronze / Silver Plating Insulator TPX Body Brass / Trimetal Plating Gasket Silicon Rubber Electrical Specifications Characteristics Impedance 50 Ohm Frequency Range DC~6GHz Insulation Resistance ≥10000MΩ Dielectric Withstanding Voltage 2500V rms Operating Voltage 1400V rms Center contact resistance ≤1.5 mΩ Outer contact resistance ≤1.5mΩ Insertion Loss @DC-2.7 GHz ≤0.10dB VSWR @0.8-1.0 GHz ≤1.08 @1.7-2.7 GHz ≤1.10 PIM3(2*43dBm) ≤-160dBc Environmental & Mechanical Specifications Durability (matings) ≥500 cycles Mechanical Shock Test Method MIL-STD-202, Method 213, Test Condition D Vibration Test Method MIL-STD-202, Meth. 204, Cond. A Temperature Range -65°C to +85°C RoHS Compliant Sealing Class IP68 24hr, 1m, 20℃ Regulatory Compliance / Certification ISO 9001:2015 Compliant The facts and figures contained herein are carefully complied to the best of our knowledge, but they are intended for general informational purposes only.
  • 4310 Straight Female Connector
    4310 Straight Female Connector for 1-5/8 Flexible RF Cable
    Material and Plating Inner Conductor Pin Brass / Silver Plating Inner Conductor Socket Tin Bronze / Silver Plating Insulator TPX Body & Outer Conductor Brass / Trimetal Plating Gasket Silicon Rubber Electrical Specifications Characteristics Impedance 50 Ohm Frequency Range DC~2.7GHz Insulation Resistance ≥5000MΩ Dielectric Withstanding Voltage 2500V rms Operating Voltage 1400V rms Center contact resistance ≤1.5 mΩ Outer contact resistance ≤1.5mΩ Insertion Loss @DC-2.7 GHz ≤0.10dB VSWR @0.8-1.0 GHz ≤1.08 @1.7-2.7 GHz ≤1.13 PIM3(2*43dBm) ≤-155dBc Environmental & Mechanical Specifications Durability (matings) ≥500 cycles Mechanical Shock Test Method MIL-STD-202, Method 213, Test Condition D Vibration Test Method MIL-STD-202, Meth. 204, Cond. A Temperature Range -65°C to +85°C RoHS Compliant Sealing Class IP68 24hr, 1m, 20℃ Regulatory Compliance / Certification ISO 9001:2015 Compliant The facts and figures contained herein are carefully complied to the best of our knowledge, but they are intended for general informational purposes only.
  • Anti-corrosion Primer
    Primer for Anti-Corrosion Tape
    The anticorrosive primer and PE anticorrosive tape together constitute the polyethylene cold wound anticorrosive system. Coated on the surface treatment of steel tube, can fill a small bump on the surface of the steel tube, and can increase the adhesive tape with sticky relay between steel tube, at the same time it is also a kind of excellent corrosion inhibitor.
  • High Precision insulating joint
    64/110KV YJZGG Prefabricated Insulating Joint/ Straight Through Joint For 64/110kv Xlpe Cable

    1. The body of joint is made of imported silicone rubber with good quality, so it is with high strength, elasticity and tear resistance as well as excellent thermal

    aging resistance.

    2. The body of joint has integral pre-fabricate structure with high voltage shielded, stress cone and insulating injection pressed integration, so it has excellent properties and easy to test as well as install.

    3. The body of joint is analized and computed optimization by finite element software, so it has more resonable field-intensity distribution and high insulation safety margin.

    4. The body of insulating joint and straight through joint is the same, the d ifference is just the handling of shielding on-site installation, insulating joint with one side insulated and the rest shielded while staight through joint full shielded.

    5. The joint has completely sealed structure with high mechanical strength and good sealing performance.

    6. Joint protecting is made of insulating copper case with high-intensitive T2 copper, and the moulded high-density PE material of its external surface is used for insulation and anti-corrosion with good mechanical protection and permanent waterproof sealing performance, which ensure the joint to run safely and reliably in the long-term under harsh environment.In addition, it can equip glass fiber reinforced plastic protective box as a strengthen waterproof measure accordingly.

    7. Special installer tools make the installation more convenient.

  • Busbar Insulation Tube
    Heat Shrinkable Busbar Insulation Tube

    Designed for insulation of copper and aluminum busbars- for electrical substations and switchgear cabinets. Can be used for exterior installations

    Shrink ratio: 2.5:1

    Operating voltage: 35 kV

    Material: polyolefin, halogen-free «HF»

    Analogs: BPTM (Raychem); BBI (3M)

    Resistant to the phenomenon of tracking and UV radiation

    High dielectric strength

    Color: brick red

    The use of tubes ТТШ allows shortening the distance between phase busbars and significantly reducing the dimensions of the device

    Protects electrical busbars against chemical corrosion

    Protects equipment from short circuits in case of contact of electrical devices with animals and birds

1 ... 9 10 11 12 13 14 15

A total of 15 pages

Subscribe
Subscribe to our newsletter and stay up to date with the latest news and deals !

click here to leave a message

Leave A Message
If you are interested in our products and want to know more details,please leave a message here,we will reply you as soon as we can.

Home

Products

About

contact